Digital Stationary X Ray Machine With Double Column
1. X Ray Machine Parameter
Parameter/Model : MCDX320 MCDX500 MCDX650
Power 32kW 50kW 65kW
Power supply: 50HZ、 60HZ, wire diameter 4mm2, internal resistance0.5Ω; 20/32/50kW(220V/380V available),65kW(only 380V).
mA : 10-400 10-630 10-800
mAS: 0.4--320 0.4--1000 0.4--1000
KV: 40—125kVstepping by 1kV 40—150kV stepping by 1kV
Exposure time: 0.003~6.3s(34 steps)adjustment: Increased/reduced by 1mS each time
Focus size Default: 0.6*0.6mm/1.2*1.2mm dual focus, Toshiba (optional)
Anode rotating: 2800prm/1300kHU 8400prm/1300kHU
Generator frequency : 30kHZ/400kHZ(optional)
Radiography table(W*L cm): 73*200cm, Move 40cm left and right, 20cm back and forth
Additional Information
1. X Ray Machine Parameter
Parameter/Model : MCDX320 MCDX500 MCDX650
Power 32kW 50kW 65kW
Power supply: 50HZ、 60HZ, wire diameter 4mm2, internal resistance0.5Ω; 20/32/50kW(220V/380V available),65kW(only 380V).
mA : 10-400 10-630 10-800
mAS: 0.4–320 0.4–1000 0.4–1000
KV: 40—125kVstepping by 1kV 40—150kV stepping by 1kV
Exposure time: 0.003~6.3s(34 steps)adjustment: Increased/reduced by 1mS each time
Focus size Default: 0.6*0.6mm/1.2*1.2mm dual focus, Toshiba (optional)
Anode rotating: 2800prm/1300kHU 8400prm/1300kHU
Generator frequency : 30kHZ/400kHZ(optional)
Radiography table(W*L cm): 73*200cm, Move 40cm left and right, 20cm back and forth
Computer Room Installation Instructions
1. X-ray room: 20m2 room is recommended.
2. Lead glass size recommended: 40*60cm or 60*80 cm
3. X-ray protection preparation: use barium sulfate powder or lead sheet for the wall of the room, and lead sheet
for the ceiling;
4. A fan must be installed on the top to facilitate the discharge of ionized air
5. All surfaces of the x-ray room that people can reach need to be covered with lead sheet or barium sulfate
powder. If it is the first floor, the ground does not need to be covered; if it is the top floor and will not polluted the
environment, lead protection is not required.
Service and Support
1. With more than 10 years of X-ray product R&D and production experience, we can provide more cost-effective
and suitable products;
2. The components of X-ray machine including flat panel detector, can be installed and debugged according to
the specifications required by the customer;
3. OEM customization is available for table LOGO and software interface;
4. The x-ray table can be designed and made according to the customer’s drawings, and a confidentiality
agreement can be signed for the clients