Features
* Elegant appearance, clear marks, standard interface, OXYCRG SCREEN, trend graph, big characters, other BED observation, which are convenient for user.
* Be applicable for adult, pediatric and neonatal.
* Standard parameters of ECG, RESP, NIBP, SPO2 and dual-channel TEMP. IBP, CO2, Built-in printer, curving handle, moving bracket and hanging bracket are optional.
* Operation interface with Chinese and English. Finish all operations by keys and knobs.(Optional languages: Spanish, French, English, Portuguese, Turkish, German and so on) design with full built-in module, stable and reliable performance.
* 12.1'' color TFT LCD with high resolution displays patient parameter and waveform, and alarm, bed NO,clock,state and other information provided by the monitor synchronously.
* Monitoring contents, scan speed, volume and output contents can be set optionally.
* Storage of 480-hour trend data, and review of 40-second holographic waveform.
* Storage and review of 72-hour ECG waveform.
* Function of NIBP review, storage for up to 2400 NIBP data.
* Adopt digital SPO2 technology, which has strong anti-interference and antiweak filling capability.
* Calculation of drug concentration.
* Network: connecting with central station, other Bed observation and software updating. Connection mode: wireless and wired.
* Built-in rechargeable battery for uninterrupted monitoring.
* Print ECG, SpO2, RESP, BP and temperature data with one-key.
* Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).
* Analysis function for heart rate variability(HRV) (optional).
Introduction
This equipment can monitor such parameters as ECG,RESP,SPO2,NIBP,and Dual- channel TEMP.It integrates parameter measuring module,display and recorder in one device to form a compact and portable device. At the same time, its built-in replaceable battery provides convenience for patient moving.
Accessories
1. Adult SpO2 probe(5-pin)
2. Adult NIBP cuff
3. Extending tube for blood pressure
4. ECG lead
5. ECG electrode
6. Temperature probe
7. Power cord
8. Thermal recording paper(optional)
9. User Manual
Performance
ECG:
Lead Mode 3-lead and 5-lead are optional
Lead Selection I, II, III, AVR, AVL, AVF, V
Wave 5-lead: 2 channels
3-lead: 1channel
Gain ×2.5mm/mV, ×5.0mm/mV, ×10mm/mV, ×20mm/mV
HR Measuring and Alarm Range
Range 15 ~ 300 bpm
Accuracy ±1% or ±1bpm, which is greater
Alarm Accuracy ±2bpm
Resolution 1 bpm
CMRR:
Monitor ≥ 100 dB
Surgery ≥ 100 dB
Diagnosis ≥ 60 dB
Bandwidth:
Surgery 1 ~ 20 Hz(+0.4dB,-3dB)
Monitor 0.5 ~ 40 Hz(+0.4dB,-3dB)
Diagnosis 0.05~75Hz(+0.4dB,-3dB); 76Hz~150Hz(+0.4dB,-4.5dB)
Calibration Signal 1 mV (Vp-p), ±5% Accuracy
ST Segment Monitoring:
Measuring and Alarm Range -0.6 mV~ + 0.8 mV
ARR:
ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm:
Available
Review:
Available
Scan Speed for ECG Waveform is adjustable:
12.5mm/s accuracy ±10%25mm/s accuracy±10%
50mm/s accuracy±10%
Respiration:
Method R-F(RA-LL) Impedance
Differential Input Impedance 2.5 MΩ
Measuring Impedance Range 0.3~5.0Ω
Baseline Impedance Range 100Ω– 2500Ω
Bandwidth 0.3 ~ 2.5 Hz
Resp. Rate:
Measuring and Alarm Range 0~120rpm
Resolution 1 rpm
Measuring Accuracy ±2 rpm
Alarm Accuracy ±3rpm
Apnea Alarm 10 ~ 40 S
NIBP:
Method Oscillometry
Mode Manual, Auto, continuous
Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90/120/240/480/960 Min
Measuring Period in Continuous Mode 5 Min
Measuring and Alarm Range 10~270mmHg
Alarm Type SYS, DIA, MEAN
Resolution:
Pressure 1mmHg
Cuff Pressure ±3 mmHg
Accuracy ±10% or ±8mmHg, which is greater
Over-pressure Protection:
Adult Mode 315±10 mmHg
Pediatric Mode 265±10 mmHg
Neonatal Mode 155±10 mmHg
SPO2:
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy 70% ~ 100% ±2%
0% ~ 69% unspecified
Pulse Rate(PR):
Measuring and Alarm Range 0~250bpm
Resolution 1bpm
Measuring Accuracy ±2bpm or ±2%, which is greater
Alarm Accuracy ±2bpm
TEMP:
Channel dual-channel
Measuring and Alarm Range 0 ~ 50°C
Resolution 0.1°C
Accuracy ±0.1°C
Actualization Interval about 1 Sec.
Average Time Constant 10 Sec.
Alarm responding Time ≤2min
ETCO2:
Method Sidestream or Mainstream
Measuring Range for CO2 0~150mmHg
Resolution for CO2:
0.1 mm Hg 0 to 69 mm Hg
0.25 mm Hg 70 to 150 mm Hg
Accuracy for CO2: 0 – 40 mm Hg ±2 mm Hg
41 – 70 mm Hg ±5%
71 – 100 mm Hg ±8%
101 – 150 mm Hg ±10%
Respiration Rate80BPM ±12%
AwRR Range 2~150 rpm
AwRR Accuracy ±1BPM
Apnea Alarm Available
IBP:
Channel dual-channel
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and Alarm Range -50~350 mm Hg
Resolution 1 mm Hg
Accuracy ±2% or 1mm Hg, which is greater
Display Mode 12.1" color TFT LCD with high-resolution.
Power Supply 220V, 50Hz
Safety Classification class Ⅰ,type CF defibrillation-proof part
Physical Characteristic: Dimension 380×350×300(mm) Net weight 4.8Kg